Question of the Week: Why Does My Solar Water Heater Run At Night?

[vc_row][vc_column][vc_column_text]

solar water heating, solar energy, residential solar panel“If my collector is at 136 degrees, my TST (bottom of tank temperature) is at 161 degrees and my S3 (top of the tank temperature) is at 154 degrees – why is my circulator pump still running? Won’t this cool the bottom of the tank?”

SES says: The pump runs intermittently for a minute periodically when the collectors reach 240 degrees. This keeps the collectors from overheating. Your maximum tank temperature is set to 160. If the bottom sensor, the TST reading, exceeds 160 degrees, the controller will run the pump briefly in the evening to bring the tank temperature back down to 160.

It has been our experience that setting the max temp higher than 160 leads to overheating problems. Yes, you are losing a little heat from the tank when the cooling feature comes on, but at this time of year it is excess heat. You are producing much more hot water than you are using at this time. This is the summer solstice; the collector and tank temperatures will moderate in a few months. Some customers add an extra loop to their solar tank and use that excess heat to heat a swimming pool or hot tub. Most just use control features to manage the excess heat.

Don’t worry about the power consumption. The Grundfos Alpha pump only uses about 5 Watts whether heating or cooling the tank.

[/vc_column_text][/vc_column][/vc_row]